How the MCP server handles solutions created with a different FrameworX version, and how to point an MCP client at a specific installed version.

AI IntegrationMCP SDK Reference → MCP Version Mismatch Handling


Starting with FrameworX 10.1.5, multiple product versions can be installed side-by-side on the same machine (10.1.4 on .NET 8 and 10.1.5 on .NET 10 run as isolated runtimes by design). When an MCP client attaches to a DesignerMCP server for a given version and then requests a solution that was created with a different version, the server must decide whether to open it directly, refuse, or hand control back to the LLM so the user can choose.

This page covers what happens in each case, the structured JSON responses the LLM sees, and how to reconfigure an MCP client to target an older installed version when needed.


Compatibility Baselines

Two facts drive every routing decision:

  • 10.1.0 through 10.1.4 are patch releases of the same baseline. They are interchangeable — any 10.1.x Designer in this range can open any 10.1.0-10.1.4 solution. Crossing inside the baseline does not require a prompt or an explicit upgrade.
  • 10.1.5 introduces a new baseline. Crossing from 10.1.0-10.1.4 into 10.1.5 is an explicit upgrade (schema migration + backup). Crossing the other way is not possible — 10.1.5 solutions cannot be opened by a 10.1.4 Designer.

Legacy 9.2 and earlier (.tproj) solutions are out of scope for MCP. Use Solution Center to upgrade them first.


Routing Outcomes

When open_solution (DesignerMCP / ConsoleMCP) or open_workspace (ConsoleMCP) is called, the MCP server reads the solution's ProductVersion and compares it to the running server's version. One of three outcomes applies.

Outcome

When it applies

What the LLM sees

Open directly

Same version, or solution is in the 10.1.0-10.1.4 baseline range and the running server is in the same baseline, or solution is older than the running server and no side-by-side install of the older version exists.

Normal success response. If the solution is crossing a baseline, the Designer silently creates a versioned backup (_fx-10.1.4.dbsln) and migrates the schema on open.

Prompt upgrade

Solution is older than the running server AND the matching older version is currently installed side-by-side (the user has a genuine choice).

Structured JSON with versionMismatch: true and two options: upgrade (call open_solution again to let the running server migrate with backup) and use_older_version (reconfigure the MCP client to point at the older installed version's DesignerMCP.dll). See the response example below.

Version newer (cannot open)

Solution was created with a version newer than the running server.

Error with code VERSION_NEWER and a message identifying both the solution version and the running version. The user must install a newer product version and reconfigure the MCP client.


Prompt-Upgrade Response Format

When the server returns Prompt upgrade, the response is success-shape JSON (not an error) so the LLM can present the options in chat rather than fail the turn:

{
  "success": false,
  "versionMismatch": true,
  "solutionVersion": "fx-10.1.4",
  "runningVersion": "fx-10.1.5",
  "solutionName": "Demo",
  "message": "Solution 'Demo' was created with version fx-10.1.4. This MCP server is running version fx-10.1.5.",
  "options": [
    {
      "option": "upgrade",
      "description": "Upgrade the solution from fx-10.1.4 to fx-10.1.5. A backup will be created automatically. To proceed, call open_solution again — the upgrade happens automatically."
    },
    {
      "option": "use_older_version",
      "description": "Keep the solution at version fx-10.1.4. The user must change their MCP server configuration to point to the older version's DesignerMCP: C:\\Program Files\\Tatsoft\\FrameworX\\fx-10.1.4\\net8.0\\DesignerMCP.dll"
    }
  ]
}

LLM retry semantics

If the user accepts the upgrade, the LLM calls open_solution a second time for the same solution. The server remembers that the version mismatch has already been surfaced for that solution name and bypasses the check on the retry — the second call proceeds directly into the normal open flow, which creates the versioned backup and migrates the schema transparently.

The bypass is per-solution-name and applies only to PromptUpgrade. The VERSION_NEWER outcome is not bypassed on retry: a solution that requires a newer product version cannot be opened no matter how many times the LLM is asked, so the server keeps refusing until the product is updated.


Pointing an MCP Client at a Specific Installed Version

When the user chooses use_older_version, the fix is in the MCP client configuration — not in FrameworX. Replace the DesignerMCP.dll path with the one that matches the solution's version.

Install-Path Convention

FrameworX 10.1.5 installers place each version in its own folder under C:\Program Files\Tatsoft\FrameworX\. The runtime subfolder depends on the version's .NET target.

Solution / running version

DesignerMCP path

10.1.0 – 10.1.4 (net8.0)

C:\Program Files\Tatsoft\FrameworX\fx-10.1.4\net8.0\DesignerMCP.dll

10.1.5 and later (net10.0)

C:\Program Files\Tatsoft\FrameworX\fx-10.1.5\net10.0\DesignerMCP.dll

The fx-10.1.X folders are created by the installer and exist as long as the matching version is installed side-by-side. The default fx-10 folder used by earlier documentation continues to point at the primary installed version; the versioned folders are the stable path for multi-version setups.

Example: Claude Desktop

To target 10.1.4 from Claude Desktop, edit %APPDATA%\Claude\claude_desktop_config.json:

{
  "mcpServers": {
    "FrameworX-Designer": {
      "command": "dotnet",
      "args": [
        "C:\\Program Files\\Tatsoft\\FrameworX\\fx-10.1.4\\net8.0\\DesignerMCP.dll"
      ],
      "transport": "stdio"
    }
  }
}

Save the file, fully quit Claude Desktop, and relaunch. The MCP server that starts up is now the 10.1.4 server — the versionMismatch response disappears for 10.1.4 solutions.

Example: VS Code GitHub Copilot

For Copilot, edit mcp.json (Command Palette → MCP: Open User Configuration) and use the same versioned path in args:

{
  "servers": {
    "FrameworX-Designer": {
      "type": "stdio",
      "command": "dotnet",
      "args": [
        "C:\\Program Files\\Tatsoft\\FrameworX\\fx-10.1.4\\net8.0\\DesignerMCP.dll"
      ]
    }
  }
}

Restart the MCP server from MCP: List Servers after saving.

The use_older_version choice is a one-time reconfiguration per solution — it changes which MCP server Claude talks to, not which FrameworX Designer runs. Once pointed at the 10.1.4 server, the user continues to work on the 10.1.4 solution with the 10.1.4 Designer until they decide to upgrade.


Troubleshooting

Symptom

Likely cause

Fix

VERSION_NEWER error on open_solution

The solution was created with a product version newer than the MCP server. This is expected behavior — the server refuses on purpose to protect the file.

Install the newer product version side-by-side, then edit the MCP client config to point at the newer DesignerMCP.dll.

LLM keeps receiving versionMismatch: true after the user accepted the upgrade

The second open_solution call used a different solution name or path than the first, so the per-solution bypass did not apply.

Call open_solution with the same solution_name as the first call. The bypass is keyed by that exact name.

No prompt appears when opening a 10.1.3 solution on 10.1.5

10.1.3 is inside the 10.1.0-10.1.4 baseline. The server opens it directly — no prompt is expected in this case.

None. The Designer will silently create a versioned backup if any schema migration is needed.

use_older_version path points to a DLL that does not exist

The older product version was uninstalled after the solution was created, or the folder layout was customized at install time.

Reinstall the matching version, or accept upgrade instead to migrate the solution onto the currently running version.