Comment: Template is also available for Windows (.NET 4.8); note MesRuntimeTools build error there

...

  • FrameworX 10.1.6 or later, . The template is available for Multi-Platform (.NET 10) solution. The template ships only for Multi-Platform) and Windows (.NET Framework 4.8) solutions. On Windows, the AI tools class does not compile (see Known limitations).

  • A PostgreSQL server reachable from the FrameworX server, with a database for MES data and the MES tables created (see Known limitations).

  • The Npgsql provider, used by the MES_PG connection.

...

  1. In Solution Center, click New....

  2. Choose the product series , then and the platform (Multi-Platform or Windows).

  3. Enter the solution name and select the MES template.

  4. Click Create New Solution.

...

The class MesRuntimeTools exposes MES read and write operations (plant model, equipment state, downtime and production lists, OEE, Pareto, reason tree, open/close downtime, corrections) as tools for AI clients connected to the FrameworX AI Runtime. Custom tools must be enabled in the solution settings for the runtime to load them. In 10.1.6 the class compiles only in Multi-Platform solutions.

Known limitations

Limitation

What to do

The template does not create the MES database tables (downtime events, production events, KPI data, curation log).

Contact Tatsoft support for the database schema before running the MES functions.

The OEE Performance factor is a placeholder value between 0.85 and 1.0, not a calculation from production counts.

Treat OEE and Performance values as indicative only.

Reason categories (Planned, Unplanned) are not read from the MES/Reasons tree. Downtime is counted as unplanned unless its reason is in the built-in planned list.

Expect Availability to be lower than actual when planned stops are recorded.

In Windows (.NET Framework 4.8) solutions, the MesRuntimeTools class fails to build with error CS0234 (System.Text.Json is not available). The other MES classes build normally.

If you do not use the AI tools, delete the MesRuntimeTools class and rebuild. To use them, create the solution as Multi-Platform.

The starter screens have no navigation menu, and the downtime Edit and Recategorize buttons are not wired.

Add navigation and your own correction dialog.

...