These changes affect how an existing solution, script or integration behaves on 10.1.6. The complete list is in Update 6 - Detailed Release Notes.
ChangeNew Behavior | Action |
|---|---|
The MCP-over-HTTP servers of AI Designer, AI Console and AI Runtime accept connections only from the same computer until an API key is configured. | To connect from another computer, set an API key in the server settings and enter the same key in the client. See MCP and Claude Setup. |
The Runtime API accepts a session token only from a Runtime API sign-in or a bearer token linked to a user, and enforces each tag's Read Security and Write Security. | Update custom Runtime API callers to sign in through the Runtime API or use a bearer token linked to a user, and review the security of the tags they read and write. |
An AutoStartClient from an earlier release cannot check which redundant server is active on a server of this release. | Install the AutoStartClient from this release on every station that connects to a 10.1.6 server. |
Clients on other computers receive blank values for stored passwords and secrets in the configuration tables. | Update any client-side script that read stored passwords or secrets from the configuration tables. |
A user who signs in through an external identity provider and matches a user in the solution receives that user's permission groups, and the provider's group claims are ignored. | Review the permission groups of solution users who sign in through an external identity provider. |
On clients connected with Windows authentication, electronic signatures and alarm acknowledgment comments check the Windows password of the user named, in the server's own domain only. | Have operators sign with their Windows password, and use accounts from the server's domain. |
File and process services between FrameworX computers accept only allowed folders and FrameworX programs. | Add each folder used for remote solution loading or file transfer to the allowed folders in the machine settings, and restart the service. |
On Windows, the runtime reads start settings and .NET 10 database provider registrations only from the installation folder, and a start settings file is selected by solution and profile. | Move start settings and custom provider registrations from the shared settings folder to the installation folder, and place them again after installing a new release. |
Dataset filters and queries refuse to run when a value from a tag or from the signed-in user would end a quoted text in the SQL command. | Test Dataset queries and table filters after upgrading, and where a value closes the quotes on purpose, move the quotes from the query into the value. |
A Linux or Docker runtime refuses to start a solution that targets Windows. | Open the solution in the Designer, change the target platform to Multiplatform in Solution Settings and run Build All. |
Client stations receive tag values from the server after a reconnection or an online configuration change. | Update every Smart Client and Rich Client, local and remote, to this release. |
...