Home → Support Resources → Release Notes → Update 6
...
| Info |
|---|
Update 6 installs side by side with 10.1.5, in its own installation folder. Moving your solutions to 10.1.6 is strongly recommended: this version brings important advances in connectivity, security, redundancy, displays and the AI tools that make the move worthwhile. Your 10.1.5 installation stays in place and available as a fallback while you migrate. |
FrameworX 10.1 Update 6
Version: 10.1.6
Release Date: October 15, 2026
Type: Minor Version
Update 6 installs side by side with 10.1.5. It does not replace a 10.1.5 installation. Both versions run on the same computer, and you open each solution from Solution Center.
...
- Charts. Heatmap, Pareto, waterfall, bullet, sparkline, histogram, SPC control, funnel and radar charts, on the Rich Client and the web client.
- Displays and web client. Embedded displays accept parameters, Sankey charts render in the web client, and web client URLs carry the display and its parameter values.
- Connectivity. Kafka Producer and Consumer connectors, a Siemens S7-1200 and S7-1500 Symbolic connector, and a built-in CODESYS simulatorand ControlLogix simulators.
- Alarms and redundancy. Alarm notifications reach a webhook, an MQTT broker, and the iPhone and iPad app. The standby server returns unreplicated history to the active server.
- AI. AI Chat calls the custom MCP tools of the solution. The AI Designer drives the script debugger and connects display elements.
- Security. SAML 2.0 sign-in, and stricter access rules for the MCP-over-HTTP servers and the Runtime API.
- Designer and scripts. The display editor stays responsive on large displays. The script editors add Go to Definition and solution-wide namespace declarations.
...
- A Kafka Producer connector streams tag values to Apache Kafka clusters with no middleware. See Kafka Producer Connector.
- A Kafka Consumer connector reads Apache Kafka topics into FrameworX tags. See Kafka Consumer Connector.
- The CODESYS PLC Handler driver includes a built-in simulator that needs no controller or network. See Codesys PLC Handler Connector.
- The Siemens S7-1200 and S7-1500 Symbolic Connector reads and writes PLC variables by symbol, including optimized data blocks.
- The ControlLogix Simulator runs a ControlLogix channel with no PLC, launched from Devices > Channels.
Alarms, Historian and redundancy
...
- Operators sign in to runtime clients through SAML 2.0 identity providers. See Security Identity Providers Reference.
- Administrators can reveal and copy a stored secret value from the Security Secrets editor. See Security Secrets Reference.
- The Runtime API requires a signed-in session or a bearer token linked to a user. See Runtime REST API Reference.
- The runtime server keeps stored passwords and secrets on the server.
- The SolutionCenter API is available for administrators who enable it.
Runtime and platform
- FxResourceMonitor records CPU and memory of every FrameworX runtime process on Windows. See FxResourceMonitor Reference.
- Runtime diagnostics and System Monitor values work on .NET 10 runtimes on Windows, Linux and macOS. See Runtime Diagnostics Reference.
- Opening a solution from an earlier version always saves a backup copy before the upgrade. See Upgrading Solutions Reference.
- Designer, Solution Center and runtime clients reconnect after a lost server connection without a restart.
- Reconnecting client stations receive the current tag values from the server.
...
Changes to Review Before Upgrading
...
Change | Action |
|---|---|
The MCP-over-HTTP servers of AI Designer, AI Console and AI Runtime accept connections only from the same computer until an API key is configured. | To connect from another computer, set an API key in the server settings and enter the same key in the client. See MCP and Claude Setup. |
The Runtime API accepts a session token only from a Runtime API sign-in or a bearer token linked to a user, and enforces each tag's Read Security and Write Security. | Update custom Runtime API callers to sign in through the Runtime API or use a bearer token linked to a user, and review the security of the tags they read and write. |
An AutoStartClient from an earlier release cannot check which redundant server is active on a server of this release. | Install the AutoStartClient from this release on every station that connects to a 10.1.6 server. |
Clients on other computers receive blank values for stored passwords and secrets in the configuration tables. | Update any client-side script that read stored passwords or secrets from the configuration tables. |
A user who signs in through an external identity provider and matches a user in the solution receives that user's permission groups, and the provider's group claims are ignored. | Review the permission groups of solution users who sign in through an external identity provider. |
On clients connected with Windows authentication, electronic signatures and alarm acknowledgment comments check the Windows password of the user named, in the server's own domain only. | Have operators sign with their Windows password, and use accounts from the server's domain. |
File and process services between FrameworX computers accept only allowed folders and FrameworX programs. | Add each folder used for remote solution loading or file transfer to the allowed folders in the machine settings, and restart the service. |
On Windows, the runtime reads start settings and .NET 10 database provider registrations only from the installation folder, and a start settings file is selected by solution and profile. | Move start settings and custom provider registrations from the shared settings folder to the installation folder, and place them again after installing a new release. |
Dataset filters and queries refuse to run when a value from a tag or from the signed-in user would end a quoted text in the SQL command. | Test Dataset queries and table filters after upgrading, and where a value closes the quotes on purpose, move the quotes from the query into the value. |
A Linux or Docker runtime refuses to start a solution that targets Windows. | Open the solution in the Designer, change the target platform to Multiplatform in Solution Settings and run Build All. |
Client stations receive tag values from the server after a reconnection or an online configuration change. | Update every Smart Client and Rich Client, local and remote, to this release. |
...
Compatibility and Lifecycle
...